Multi Optimization
Parallel multi-objective optimization software for TRNSYS, EES, and COMSOL — plus AI surrogates and datacenter cooling simulation
- Website
- multioptimization.com · all feeds from this site
- Feed URL
https://www.multioptimization.com/feed/
Read it in your FeedListing reader
Or add to: Feedly Inoreader Raw feed
Latest posts
-
Neural Network vs Kriging for Engineering Surrogates
Neural network vs kriging is a decision you should make on identical solver data, not on model reputation. Use the same design bounds, Latin-hypercube sample, validation split, and optimization budget. Then rerun the chosen design in the full solver. Kriging often wins small…
-
COMSOL final time optimization for event stops
COMSOL final time optimization minimizes a transient process by making the stop event define the endpoint, then evaluating the objective at that final time. You set a Stop expression, verify the trigger, and log a failure value when the event never occurs. This makes…
-
COMSOL Shape Optimization Remeshing: A Failure Test
COMSOL shape optimization remeshing is a recovery step, not a substitute for controlling deformation. Start with a bounded MMA move limit, monitor minimum element quality, and stop before inverted mesh elements appear. If the solve fails, remesh the deformed geometry, restart…
-
CFD Parameter Sweep: Choose the Right Study Design
A CFD parameter sweep maps solver outputs across chosen inputs. Use full factorial when every interaction matters and the case count is affordable; use a DOE when you need coverage under queue or license limits; use a surrogate only after verified solver results cover the design…
-
EES optimization methods: license or parallel search?
EES optimization methods are sufficient when you have one objective, bounded variables, and a license with enough optimization capacity. Choose parallel multi-objective search when you need a Pareto front, repeated EES solves, or more throughput than serial Genetic or DIRECT…
-
GB300 Cooling Requirements for NVL72
GB300 cooling requirements are a pre-deployment sizing problem, not a single flow number. Start with the rack’s 132 kW nominal TDP, test 25–45°C supply cases against 59–177 LPM, then size CDUs and pumps for rack count and a failed-pump case. Accept the design only when…
-
3D Surrogate Model: Field or KPI?
A 3D surrogate model should return a volumetric field when decisions depend on local gradients, hot spots, recirculation, boundary loads, or conservation residuals—not only averages or maxima. Use scalar KPIs when those fields cannot change the decision. For production CFD,…
-
ASHRAE 127 CDU: A Simulation-Ready Test Checklist
ASHRAE 127 CDU Addendum b turns liquid-to-liquid CDU work into a steady-state laboratory rating problem: define TCS and FWS, measure both loops, calculate net capacity, critical input power, CDU thermal efficiency, pressure drop, and energy balance, then report the rating…
-
COMSOL Multiphysics Price: A 2026 Workload Guide
comsol multiphysics price is not one universal commercial number. In 2026, your cost depends on license type, required modules, term or perpetual purchase, support renewal, and concurrent evaluations. A named-user license may suit one engineer, but distributed cluster…
-
Data Center Coolant Quality in Cooling Models
DCX’s 14 October 2026 announcement makes data center coolant quality an engineering input, not a dashboard status. You should convert pH, conductivity, turbidity, glycol concentration, and corrosion readings into fluid-property or deposit assumptions, then quantify pressure…