How to Choose the Right ITAD Company: A Complete Checklist for Data Security, Compliance & Value Recovery
Reading Time: 5 minutes When your organization retires outdated hardware, choosing a trusted IT asset disposition (ITAD) company is crucial. The right provider safeguards sensitive data, ensures regulatory compliance, and supports sustainability goals. The wrong one can expose…
-
DDR3 vs DDR4 vs DDR5 Server RAM: Specs & Compatibility
Reading Time: 7 minutes A server refresh can leave an IT team with hundreds of DIMMs that look similar but belong to different platforms. Even when the generation matches, a module can fail because of its rank, type or slot population rules. Knowing the difference between DDR3,…
-
How to See What RAM You Have: Type, Speed & Size
Reading Time: 10 minutes Not sure what kind of RAM your computer has? You can check your installed memory in seconds using Windows Task Manager. Just press Ctrl + Shift + Esc, select Performance, and click Memory to see your RAM capacity and speed. If you’re working with loose…
-
Why the Whipsaw? What the Post-Election AI Data Center Swing Means for IT Hardware
Reading Time: 3 minutes In the 48 hours after the November 3 midterms, the market swung hard both ways, and data centers were at the center of it. On Wednesday, the Dow jumped about 1,500 points. On Thursday, the S&P 500 fell more than 4% and the Nasdaq more than 5%. It was the…
-
Is RAM Volatile? What Happens to Data When Power Is Lost?
Reading Time: 6 minutes Yes, RAM (Random Access Memory) is volatile, meaning it requires power to retain data. When power is removed, conventional RAM loses its stored data as the electrical states representing that data decay. Unlike SSDs and hard drives, standard RAM is not…
-
When Resale Offsets Decommissioning Cost and When It Doesn’t
Reading Time: 5 minutes Resale can absolutely offset decommissioning cost. Sometimes it offsets a meaningful portion of it. Sometimes it changes the entire financial shape of the project. And sometimes it barely dents the bill because: Resale is not a bonus feature bolted onto a…
-
GPU Procurement in 2026: What the Quote Doesn’t Tell You
Reading Time: 4 minutes Most published guidance on GPU procurement stays on the quote: lease vs. buy vs. rent, and the utilization rate at which each one wins. Servers that arrive at a cage wired for half their draw, secondary-market lots with no transferable warranty, and…
-
Why Server Memory Prices Are Still Climbing in Q4 2026, And When That Might Change
Reading Time: 10 minutes In early July, TrendForce told memory buyers to expect a calmer third quarter, forecasting conventional DRAM contract prices up 13-18% after a 58-63% jump in Q2. Within a week, Taiwanese module maker ADATA said its suppliers were notifying customers of…
-
Used vs. New GPU For Your Servers: How to Choose
Reading Time: 5 minutes The demand for GPUs is spiking, leaving new GPUs less accessible across the board. Some customers will have to pay a premium for GPUs, and others will be boxed out of the market entirely. More and more customers are forced to rely on the GPU resale market…
-
Used Server Buyback in 2026: What Depreciates First
Reading Time: 3 minutes There are lots of ways to make use of old servers, but there’s one big mistake to avoid: the waiting game. The longer those servers sit in a box, the more their value drops. The best bet is to learn what your gear is worth on the secondary market, and if…
-
Guide To Liquid Cooling Decommissioning And Retirement
Reading Time: 4 minutes Most GPU decommissioning playbooks were written for gear you unplug and roll out. What happens when they’re high-density D2C racks? A liquid-cooled rack adds a drain sequence, a fluid you must identify before you can legally dispose of it, and paperwork…
-
Data Center Interconnect: What It Gets You And What To Test
Reading Time: 4 minutes Data Center Interconnect, or DCI, gets sold on spec sheets full of gigabits per wavelength and latency guarantees. Whether it holds up gets decided by things that you have to oversee like route-miles of glass, shared rights-of-way, and which layers of the…
-
How Server Sprawl Grows And How To Fight It
Reading Time: 4 minutes Some estimates find that 30% of on-site servers have delivered no useful computing for six months or more. The Uptime Institute’s 2026 Global Data Center Survey only found about 42% of operators collect server utilization data at all. With these…
-
Data Center Capacity Planning: Why MW Isn’t The Full Story
Reading Time: 4 minutes Data center capacity gets quoted as a single number, usually in MW, because a single number is easy to put in a lease. MW estimates matter, but it’s far from the whole picture. You’re missing context about the amount of racks a facility can support or the…